DCDC_0

Peripheral Memory Blocks

address_offset : 0x0 Bytes (0x0)
size : 0xFFC byte (0x0)
mem_usage : registers
protection : not protected

Registers

CONTROL

CONFIG


CONTROL

Module Control
address_offset : 0x0 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0

CONTROL CONTROL read-write 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Resets to Resets to 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 RDYLOWF RDYHIGHF DROPOUTF BGRDYF OSCDIS CLKSEL CLKDIV ADCSYNCEN CLKINVEN ADCCLKINVEN OUTVSEL MIEN MINPWSEL PSMD ASYNCEN ABEN BEN DCDCEN

RDYLOWF : DC-DC Converter Ready Low Flag.
bits : 0 - 0 (1 bit)
access : read-only

Enumeration:

0 : NOT_SET

The output voltage (VDC) is below the threshold set in the RDYLOWTH threshold field (RDYLOWTH).

1 : SET

The output voltage (VDC) is above the threshold set in the RDYLOWTH threshold field (RDYLOWTH).

End of enumeration elements list.

RDYHIGHF : DC-DC Converter Ready High Flag.
bits : 1 - 1 (1 bit)
access : read-only

Enumeration:

0 : NOT_SET

The output voltage (VDC) has not exceeded 105% of the programmed output value.

1 : SET

The output voltage (VDC) has exceeded 105% of the programmed output value.

End of enumeration elements list.

DROPOUTF : DC-DC Converter Dropout Flag.
bits : 2 - 2 (1 bit)
access : read-only

Enumeration:

0 : NOT_SET

The input voltage (VBATDC) is more than 0.4 V above the output voltage (VDC). The DC-DC converter is not in dropout.

1 : SET

The input voltage (VBATDC) is less than 0.4 V above the output voltage (VDC). The DC-DC converter is in dropout, and firmware should enable the bypass switch (BEN=1).

End of enumeration elements list.

BGRDYF : Bandgap Ready Flag.
bits : 3 - 3 (1 bit)
access : read-only

Enumeration:

0 : NOT_SET


1 : SET

The bandgap voltage is above the threshold.

End of enumeration elements list.

OSCDIS : Oscillator Disable.
bits : 8 - 8 (1 bit)

Enumeration:

0 : INACTIVE

Enable the DC-DC local oscillator.

1 : ACTIVE

Disable the DC-DC local oscillator.

End of enumeration elements list.

CLKSEL : Clock Source Select.
bits : 9 - 9 (1 bit)

Enumeration:

0 : DCDCOSC

Select the local DC-DC oscillator as the clock source.

1 : AHB

Select the AHB clock as the clock source.

End of enumeration elements list.

CLKDIV : Clock Divider.
bits : 10 - 12 (3 bit)

Enumeration:

0 : DIV1

Use the AHB clock divided by 1 as the converter switching frequency.

1 : DIV2

Use the AHB clock divided by 2 as the converter switching frequency.

2 : DIV4

Use the AHB clock divided by 4 as the converter switching frequency.

3 : DIV8

Use the AHB clock divided by 8 as the converter switching frequency.

4 : DIV16

Use the AHB clock divided by 16 as the converter switching frequency.

End of enumeration elements list.

ADCSYNCEN : ADC Synchronization Enable.
bits : 13 - 13 (1 bit)

Enumeration:

0 : DISABLED

Do not synchronize the ADC to the DC-DC converter.

1 : ENABLED

Synchronize the ADC to the DC-DC converter.

End of enumeration elements list.

CLKINVEN : Clock Inversion Enable.
bits : 14 - 14 (1 bit)

Enumeration:

0 : DISABLED

Do not invert the AHB clock input.

1 : ENABLED

Invert the AHB clock input.

End of enumeration elements list.

ADCCLKINVEN : ADC Clock Inversion Enable.
bits : 15 - 15 (1 bit)

Enumeration:

0 : DISABLED

Do not invert the ADC clock derived from the DC-DC switching frequency.

1 : ENABLED

Invert the ADC clock derived from the DC-DC switching frequency.

End of enumeration elements list.

OUTVSEL : Output Voltage Select.
bits : 16 - 20 (5 bit)

MIEN : Module Interrupt Enable.
bits : 22 - 22 (1 bit)

Enumeration:

0 : DISABLED

Disable DC-DC module interrupts.

1 : ENABLED

Enable DC-DC module interrupts.

End of enumeration elements list.

MINPWSEL : Minimum Pulse Width Select.
bits : 24 - 25 (2 bit)

Enumeration:

0 : DISABLED

Disable pulse skipping.

1 : 10_NS

Set the minimum pulse width to 10 ns.

2 : 20_NS

Set the minimum pulse width to 20 ns.

3 : 40_NS

Set the minimum pulse width to 40 ns.

End of enumeration elements list.

PSMD : Power Switch Mode.
bits : 26 - 27 (2 bit)

Enumeration:

0 : SWSEL0

Mode 0. Set the M1 and M2 power switches to each use one MOSFET only.

1 : SWSEL1

Mode 1. Set the M1 and M2 power switches to each use 2 MOSFETS in parallel.

2 : SWSEL2

Mode 2. Set the M1 and M2 power switches to each use 3 MOSFETS in parallel.

3 : SWSEL3

Mode 3. Set the M1 and M2 power switches to each use 4 MOSFETS in parallel.

End of enumeration elements list.

ASYNCEN : Asynchronous Mode Enable.
bits : 28 - 28 (1 bit)

Enumeration:

0 : DISABLED

Enable DC-DC synchronous mode.

1 : ENABLED

Enable DC-DC asynchronous mode. This mode is more efficient for very light output loads.

End of enumeration elements list.

ABEN : Automatic Bypass Enable.
bits : 29 - 29 (1 bit)

Enumeration:

0 : DISABLED

Disable automatic bypass.

1 : ENABLED

Enable automatic bypass.

End of enumeration elements list.

BEN : Bypass Enable.
bits : 30 - 30 (1 bit)

Enumeration:

0 : DISABLED

Disable the MBYP bypass switch.

1 : ENABLED

Enable the MBYP bypass switch.

End of enumeration elements list.

DCDCEN : DC-DC Converter Enable.
bits : 31 - 31 (1 bit)

Enumeration:

0 : DISABLED

Disable the DC-DC converter.

1 : ENABLED

Enable the DC-DC converter.

End of enumeration elements list.


CONFIG

Module Configuration
address_offset : 0x10 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0

CONFIG CONFIG read-write 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Resets to Resets to 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ILIMIT INTMD RDYLOWTH

ILIMIT : Inductor Peak Current Limit.
bits : 4 - 6 (3 bit)

Enumeration:

1 : LIMIT1

Limit the peak inductor current to 200 mA.

2 : LIMIT2

Limit the peak inductor current to 300 mA.

3 : LIMIT3

Limit the peak inductor current to 400 mA.

4 : LIMIT4

Limit the peak inductor current to 500 mA.

5 : LIMIT5

Limit the peak inductor current to 600 mA.

6 : LIMIT6

Limit the peak inductor current to 700 mA.

7 : LIMIT7

Limit the peak inductor current to 800 mA.

End of enumeration elements list.

INTMD : Interrupt Mode.
bits : 16 - 17 (2 bit)

Enumeration:

0 : OUTPUT_TOO_LOW

Generate an interrupt when the regulated converter output voltage is too low.

1 : OUTPUT_NOT_TOO_LOW

Generate an interrupt when the regulated converter output voltage is not too low.

2 : OUT_OF_REG

Generate an interrupt when the output voltage is out of regulation. The converter output can be either too high or too low.

3 : IN_REG

Generate an interrupt when the output voltage is in regulation.

End of enumeration elements list.

RDYLOWTH : Converter Ready Low Threshold.
bits : 20 - 21 (2 bit)

Enumeration:

0 : 95_PERCENT

Hardware sets the RDYLOWF flag if the regulated output voltage is greater than 95% of the programmed output voltage.

1 : 90_PERCENT

Hardware sets the RDYLOWF flag if the regulated output voltage is greater than 90% of the programmed output voltage.

2 : 85_PERCENT

Hardware sets the RDYLOWF flag if the regulated output voltage is greater than 85% of the programmed output voltage.

3 : 80_PERCENT

Hardware sets the RDYLOWF flag if the regulated output voltage is greater than 80% of the programmed output voltage.

End of enumeration elements list.