\n
address_offset : 0x0 Bytes (0x0)
size : 0x9E4 byte (0x0)
mem_usage : registers
protection : not protected
Module Configuration Register
address_offset : 0x0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MAXMB : no description available
bits : 0 - 6 (7 bit)
access : read-write
IDAM : no description available
bits : 8 - 9 (2 bit)
access : read-write
Enumeration:
#00 : 00
Format A One full ID (standard or extended) per ID filter Table element.
#01 : 01
Format B Two full standard IDs or two partial 14-bit extended IDs per ID filter Table element.
#10 : 10
Format C Four partial 8-bit IDs (standard or extended) per ID filter Table element.
#11 : 11
Format D All frames rejected.
End of enumeration elements list.
AEN : no description available
bits : 12 - 12 (1 bit)
access : read-write
Enumeration:
#1 : 1
Abort enabled
#0 : 0
Abort disabled
End of enumeration elements list.
LPRIO_EN : no description available
bits : 13 - 13 (1 bit)
access : read-write
Enumeration:
#1 : 1
Local Priority enabled
#0 : 0
Local Priority disabled
End of enumeration elements list.
IRMQ : no description available
bits : 16 - 16 (1 bit)
access : read-write
Enumeration:
#1 : 1
Individual Rx masking and queue feature are enabled.
#0 : 0
Individual Rx masking and queue feature are disabled.For backward compatibility, the reading of C/S word locks the MB even if it is EMPTY.
End of enumeration elements list.
SRX_DIS : no description available
bits : 17 - 17 (1 bit)
access : read-write
Enumeration:
#1 : 1
Self reception disabled
#0 : 0
Self reception enabled
End of enumeration elements list.
WAK_SRC : no description available
bits : 19 - 19 (1 bit)
access : read-write
Enumeration:
#1 : 1
FLEXCAN uses the filtered FLEXCAN_RX input to detect recessive to dominant edges on the CAN bus
#0 : 0
FLEXCAN uses the unfiltered FLEXCAN_RX input to detect recessive to dominant edges on the CAN bus.
End of enumeration elements list.
LPM_ACK : no description available
bits : 20 - 20 (1 bit)
access : read-only
Enumeration:
#1 : 1
FLEXCAN is either in Disable Mode, or Stop mode
#0 : 0
FLEXCAN not in any of the low power modes
End of enumeration elements list.
WRN_EN : no description available
bits : 21 - 21 (1 bit)
access : read-write
Enumeration:
#1 : 1
TWRN_INT and RWRN_INT bits are set when the respective error counter transition from <96 to >= 96.
#0 : 0
TWRN_INT and RWRN_INT bits are zero, independent of the values in the error counters.
End of enumeration elements list.
SLF_WAK : no description available
bits : 22 - 22 (1 bit)
access : read-write
Enumeration:
#1 : 1
FLEXCAN Self Wake Up feature is enabled
#0 : 0
FLEXCAN Self Wake Up feature is disabled
End of enumeration elements list.
SUPV : no description available
bits : 23 - 23 (1 bit)
access : read-write
Enumeration:
#1 : 1
FlexCAN is in Supervisor Mode. Affected registers allow only Supervisor access. Unrestricted access behaves as though the access was done to an unimplemented register location
#0 : 0
FlexCAN is in User Mode. Affected registers allow both Supervisor and Unrestricted accesses
End of enumeration elements list.
FRZ_ACK : no description available
bits : 24 - 24 (1 bit)
access : read-only
Enumeration:
#1 : 1
FLEXCAN in Freeze Mode, prescaler stopped
#0 : 0
FLEXCAN not in Freeze Mode, prescaler running
End of enumeration elements list.
SOFT_RST : no description available
bits : 25 - 25 (1 bit)
access : read-write
Enumeration:
#1 : 1
Reset the registers
#0 : 0
No reset request
End of enumeration elements list.
WAK_MSK : no description available
bits : 26 - 26 (1 bit)
access : read-write
Enumeration:
#1 : 1
Wake Up Interrupt is enabled
#0 : 0
Wake Up Interrupt is disabled
End of enumeration elements list.
NOT_RDY : no description available
bits : 27 - 27 (1 bit)
access : read-only
Enumeration:
#1 : 1
FLEXCAN module is either in Disable Mode, Stop Mode or Freeze Mode
#0 : 0
FLEXCAN module is either in Normal Mode, Listen-Only Mode or Loop-Back Mode
End of enumeration elements list.
HALT : no description available
bits : 28 - 28 (1 bit)
access : read-write
Enumeration:
#1 : 1
Enters Freeze Mode if the FRZ bit is asserted.
#0 : 0
No Freeze Mode request.
End of enumeration elements list.
RFEN : no description available
bits : 29 - 29 (1 bit)
access : read-write
Enumeration:
#1 : 1
FIFO enabled
#0 : 0
FIFO not enabled
End of enumeration elements list.
FRZ : no description available
bits : 30 - 30 (1 bit)
access : read-write
Enumeration:
#1 : 1
Enabled to enter Freeze Mode
#0 : 0
Not enabled to enter Freeze Mode
End of enumeration elements list.
MDIS : no description available
bits : 31 - 31 (1 bit)
access : read-write
Enumeration:
#1 : 1
Disable the FLEXCAN module
#0 : 0
Enable the FLEXCAN module
End of enumeration elements list.
Rx Mailboxes Global Mask Register
address_offset : 0x10 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MG31_MG0 : no description available
bits : 0 - 31 (32 bit)
access : read-write
Enumeration:
#1 : 1
The corresponding bit in the filter is checked against the one received
#0 : 0
the corresponding bit in the filter is "don't care"
End of enumeration elements list.
Message Buffer 8 CS Register
address_offset : 0x100 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 8 ID Register
address_offset : 0x104 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 8 WORD0 Register
address_offset : 0x108 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 8 WORD1 Register
address_offset : 0x10C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 9 CS Register
address_offset : 0x110 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 9 ID Register
address_offset : 0x114 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 9 WORD0 Register
address_offset : 0x118 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 9 WORD1 Register
address_offset : 0x11C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 10 CS Register
address_offset : 0x120 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 10 ID Register
address_offset : 0x124 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 10 WORD0 Register
address_offset : 0x128 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 10 WORD1 Register
address_offset : 0x12C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 11 CS Register
address_offset : 0x130 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 11 ID Register
address_offset : 0x134 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 11 WORD0 Register
address_offset : 0x138 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 11 WORD1 Register
address_offset : 0x13C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Rx Buffer 14 Mask Register
address_offset : 0x14 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
RX14M31_RX14M0 : no description available
bits : 0 - 31 (32 bit)
access : read-write
Enumeration:
#1 : 1
The corresponding bit in the filter is checked
#0 : 0
the corresponding bit in the filter is "don't care"
End of enumeration elements list.
Message Buffer 12 CS Register
address_offset : 0x140 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 12 ID Register
address_offset : 0x144 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 12 WORD0 Register
address_offset : 0x148 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 12 WORD1 Register
address_offset : 0x14C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 13 CS Register
address_offset : 0x150 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 13 ID Register
address_offset : 0x154 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 13 WORD0 Register
address_offset : 0x158 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 13 WORD1 Register
address_offset : 0x15C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 14 CS Register
address_offset : 0x160 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 14 ID Register
address_offset : 0x164 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 14 WORD0 Register
address_offset : 0x168 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 14 WORD1 Register
address_offset : 0x16C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 15 CS Register
address_offset : 0x170 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 15 ID Register
address_offset : 0x174 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 15 WORD0 Register
address_offset : 0x178 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 15 WORD1 Register
address_offset : 0x17C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Rx Buffer 15 Mask Register
address_offset : 0x18 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
RX15M31_RX15M0 : no description available
bits : 0 - 31 (32 bit)
access : read-write
Enumeration:
#1 : 1
The corresponding bit in the filter is checked
#0 : 0
the corresponding bit in the filter is "don't care"
End of enumeration elements list.
Message Buffer 16 CS Register
address_offset : 0x180 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 16 ID Register
address_offset : 0x184 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 16 WORD0 Register
address_offset : 0x188 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 16 WORD1 Register
address_offset : 0x18C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 17 CS Register
address_offset : 0x190 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 17 ID Register
address_offset : 0x194 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 17 WORD0 Register
address_offset : 0x198 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 17 WORD1 Register
address_offset : 0x19C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 18 CS Register
address_offset : 0x1A0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 18 ID Register
address_offset : 0x1A4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 18 WORD0 Register
address_offset : 0x1A8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 18 WORD1 Register
address_offset : 0x1AC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 19 CS Register
address_offset : 0x1B0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 19 ID Register
address_offset : 0x1B4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 19 WORD0 Register
address_offset : 0x1B8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 19 WORD1 Register
address_offset : 0x1BC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Error Counter Register
address_offset : 0x1C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
Tx_Err_Counter : no description available
bits : 0 - 7 (8 bit)
access : read-write
Rx_Err_Counter : no description available
bits : 8 - 15 (8 bit)
access : read-write
Message Buffer 20 CS Register
address_offset : 0x1C0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 20 ID Register
address_offset : 0x1C4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 20 WORD0 Register
address_offset : 0x1C8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 20 WORD1 Register
address_offset : 0x1CC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 21 CS Register
address_offset : 0x1D0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 21 ID Register
address_offset : 0x1D4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 21 WORD0 Register
address_offset : 0x1D8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 21 WORD1 Register
address_offset : 0x1DC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 22 CS Register
address_offset : 0x1E0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 22 ID Register
address_offset : 0x1E4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 22 WORD0 Register
address_offset : 0x1E8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 22 WORD1 Register
address_offset : 0x1EC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 23 CS Register
address_offset : 0x1F0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 23 ID Register
address_offset : 0x1F4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 23 WORD0 Register
address_offset : 0x1F8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 23 WORD1 Register
address_offset : 0x1FC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Error and Status 1 Register
address_offset : 0x20 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
WAK_INT : no description available
bits : 0 - 0 (1 bit)
access : read-write
Enumeration:
#1 : 1
Indicates a recessive to dominant transition received on the CAN bus when the FLEXCAN module is in Stop Mode
#0 : 0
No such occurrence
End of enumeration elements list.
ERR_INT : no description available
bits : 1 - 1 (1 bit)
access : read-write
Enumeration:
#1 : 1
Indicates setting of any Error Bit in the Error and Status Register
#0 : 0
No such occurrence
End of enumeration elements list.
BOFF_INT : no description available
bits : 2 - 2 (1 bit)
access : read-write
Enumeration:
#1 : 1
FLEXCAN module entered 'Bus Off' state
#0 : 0
No such occurrence
End of enumeration elements list.
RX : no description available
bits : 3 - 3 (1 bit)
access : read-only
Enumeration:
#1 : 1
FLEXCAN is transmitting a message
#0 : 0
FLEXCAN is receiving a message
End of enumeration elements list.
FLT_CONF : no description available
bits : 4 - 5 (2 bit)
access : read-only
Enumeration:
#00 : 00
Error Active
#01 : 01
Error Passive
#1x : 1x
Bus off
End of enumeration elements list.
TX : no description available
bits : 6 - 6 (1 bit)
access : read-only
Enumeration:
#1 : 1
FLEXCAN is transmitting a message
#0 : 0
FLEXCAN is receiving a message
End of enumeration elements list.
IDLE : no description available
bits : 7 - 7 (1 bit)
access : read-only
Enumeration:
#1 : 1
CAN bus is now IDLE
#0 : 0
No such occurrence
End of enumeration elements list.
RX_WRN : no description available
bits : 8 - 8 (1 bit)
access : read-only
Enumeration:
#1 : 1
Rx_Err_Counter >= 96
#0 : 0
No such occurrence
End of enumeration elements list.
TX_WRN : no description available
bits : 9 - 9 (1 bit)
access : read-only
Enumeration:
#1 : 1
TX_Err_Counter >= 96
#0 : 0
No such occurrence
End of enumeration elements list.
STF_ERR : no description available
bits : 10 - 10 (1 bit)
access : read-only
Enumeration:
#1 : 1
A Stuffing Error occurred since last read of this register.
#0 : 0
No such occurrence.
End of enumeration elements list.
FRM_ERR : no description available
bits : 11 - 11 (1 bit)
access : read-only
Enumeration:
#1 : 1
A Form Error occurred since last read of this register
#0 : 0
No such occurrence
End of enumeration elements list.
CRC_ERR : no description available
bits : 12 - 12 (1 bit)
access : read-only
Enumeration:
#1 : 1
A CRC error occurred since last read of this register.
#0 : 0
No such occurrence
End of enumeration elements list.
ACK_ERR : no description available
bits : 13 - 13 (1 bit)
access : read-only
Enumeration:
#1 : 1
An ACK error occurred since last read of this register
#0 : 0
No such occurrence
End of enumeration elements list.
BIT0_ERR : no description available
bits : 14 - 14 (1 bit)
access : read-only
Enumeration:
#1 : 1
At least one bit sent as dominant is received as recessive
#0 : 0
No such occurrence
End of enumeration elements list.
BIT1_ERR : no description available
bits : 15 - 15 (1 bit)
access : read-only
Enumeration:
#1 : 1
At least one bit sent as recessive is received as dominant
#0 : 0
No such occurrence
End of enumeration elements list.
RWRN_INT : no description available
bits : 16 - 16 (1 bit)
access : read-write
Enumeration:
#1 : 1
The Rx error counter transition from < 96 to >= 96
#0 : 0
No such occurrence
End of enumeration elements list.
TWRN_INT : no description available
bits : 17 - 17 (1 bit)
access : read-write
Enumeration:
#1 : 1
The Tx error counter transition from < 96 to >= 96
#0 : 0
No such occurrence
End of enumeration elements list.
SYNCH : no description available
bits : 18 - 18 (1 bit)
access : read-only
Enumeration:
#1 : 1
FlexCAN is synchronized to the CAN bus
#0 : 0
FlexCAN is not synchronized to the CAN bus
End of enumeration elements list.
Message Buffer 24 CS Register
address_offset : 0x200 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 24 ID Register
address_offset : 0x204 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 24 WORD0 Register
address_offset : 0x208 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 24 WORD1 Register
address_offset : 0x20C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 25 CS Register
address_offset : 0x210 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 25 ID Register
address_offset : 0x214 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 25 WORD0 Register
address_offset : 0x218 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 25 WORD1 Register
address_offset : 0x21C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 26 CS Register
address_offset : 0x220 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 26 ID Register
address_offset : 0x224 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 26 WORD0 Register
address_offset : 0x228 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 26 WORD1 Register
address_offset : 0x22C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 27 CS Register
address_offset : 0x230 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 27 ID Register
address_offset : 0x234 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 27 WORD0 Register
address_offset : 0x238 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 27 WORD1 Register
address_offset : 0x23C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Interrupt Masks 2 Register
address_offset : 0x24 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
BUF63M_BUF32M : no description available
bits : 0 - 31 (32 bit)
access : read-write
Enumeration:
#1 : 1
The corresponding buffer Interrupt is enabled
#0 : 0
The corresponding buffer Interrupt is disabled
End of enumeration elements list.
Message Buffer 28 CS Register
address_offset : 0x240 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 28 ID Register
address_offset : 0x244 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 28 WORD0 Register
address_offset : 0x248 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 28 WORD1 Register
address_offset : 0x24C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 29 CS Register
address_offset : 0x250 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 29 ID Register
address_offset : 0x254 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 29 WORD0 Register
address_offset : 0x258 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 29 WORD1 Register
address_offset : 0x25C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 30 CS Register
address_offset : 0x260 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 30 ID Register
address_offset : 0x264 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 30 WORD0 Register
address_offset : 0x268 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 30 WORD1 Register
address_offset : 0x26C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 31 CS Register
address_offset : 0x270 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 31 ID Register
address_offset : 0x274 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 31 WORD0 Register
address_offset : 0x278 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 31 WORD1 Register
address_offset : 0x27C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Interrupt Masks 1 Register
address_offset : 0x28 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
BUF31M_BUF0M : no description available
bits : 0 - 31 (32 bit)
access : read-write
Enumeration:
#1 : 1
The corresponding buffer Interrupt is enabled
#0 : 0
The corresponding buffer Interrupt is disabled
End of enumeration elements list.
Message Buffer 32 CS Register
address_offset : 0x280 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 32 ID Register
address_offset : 0x284 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 32 WORD0 Register
address_offset : 0x288 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 32 WORD1 Register
address_offset : 0x28C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 33 CS Register
address_offset : 0x290 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 33 ID Register
address_offset : 0x294 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 33 WORD0 Register
address_offset : 0x298 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 33 WORD1 Register
address_offset : 0x29C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 34 CS Register
address_offset : 0x2A0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 34 ID Register
address_offset : 0x2A4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 34 WORD0 Register
address_offset : 0x2A8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 34 WORD1 Register
address_offset : 0x2AC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 35 CS Register
address_offset : 0x2B0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 35 ID Register
address_offset : 0x2B4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 35 WORD0 Register
address_offset : 0x2B8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 35 WORD1 Register
address_offset : 0x2BC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Interrupt Flags 2 Register
address_offset : 0x2C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
BUF63I_BUF32I : no description available
bits : 0 - 31 (32 bit)
access : read-write
Enumeration:
#1 : 1
The corresponding buffer has successfully completed transmission or reception
#0 : 0
No such occurrence
End of enumeration elements list.
Message Buffer 36 CS Register
address_offset : 0x2C0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 36 ID Register
address_offset : 0x2C4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 36 WORD0 Register
address_offset : 0x2C8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 36 WORD1 Register
address_offset : 0x2CC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 37 CS Register
address_offset : 0x2D0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 37 ID Register
address_offset : 0x2D4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 37 WORD0 Register
address_offset : 0x2D8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 37 WORD1 Register
address_offset : 0x2DC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 38 CS Register
address_offset : 0x2E0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 38 ID Register
address_offset : 0x2E4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 38 WORD0 Register
address_offset : 0x2E8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 38 WORD1 Register
address_offset : 0x2EC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 39 CS Register
address_offset : 0x2F0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 39 ID Register
address_offset : 0x2F4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 39 WORD0 Register
address_offset : 0x2F8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 39 WORD1 Register
address_offset : 0x2FC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Interrupt Flags 1 Register
address_offset : 0x30 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
BUF4I_BUF0I : no description available
bits : 0 - 4 (5 bit)
access : read-write
Enumeration:
#1 : 1
Corresponding MB completed transmission/reception
#0 : 0
No such occurrence
End of enumeration elements list.
BUF5I : no description available
bits : 5 - 5 (1 bit)
access : read-write
Enumeration:
#1 : 1
MB5 completed transmission/reception or frames available in the FIFO
#0 : 0
No such occurrence
End of enumeration elements list.
BUF6I : no description available
bits : 6 - 6 (1 bit)
access : read-write
Enumeration:
#1 : 1
MB6 completed transmission/reception or FIFO almost full
#0 : 0
No such occurrence
End of enumeration elements list.
BUF7I : no description available
bits : 7 - 7 (1 bit)
access : read-write
Enumeration:
#1 : 1
MB7 completed transmission/reception or FIFO overflow
#0 : 0
No such occurrence
End of enumeration elements list.
BUF31I_BUF8I : no description available
bits : 8 - 31 (24 bit)
access : read-write
Enumeration:
#1 : 1
The corresponding MB has successfully completed transmission or reception
#0 : 0
No such occurrence
End of enumeration elements list.
Message Buffer 40 CS Register
address_offset : 0x300 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 40 ID Register
address_offset : 0x304 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 40 WORD0 Register
address_offset : 0x308 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 40 WORD1 Register
address_offset : 0x30C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 41 CS Register
address_offset : 0x310 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 41 ID Register
address_offset : 0x314 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 41 WORD0 Register
address_offset : 0x318 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 41 WORD1 Register
address_offset : 0x31C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 42 CS Register
address_offset : 0x320 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 42 ID Register
address_offset : 0x324 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 42 WORD0 Register
address_offset : 0x328 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 42 WORD1 Register
address_offset : 0x32C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 43 CS Register
address_offset : 0x330 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 43 ID Register
address_offset : 0x334 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 43 WORD0 Register
address_offset : 0x338 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 43 WORD1 Register
address_offset : 0x33C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Control 2 Register
address_offset : 0x34 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EACEN : no description available
bits : 16 - 16 (1 bit)
access : read-write
Enumeration:
#1 : 1
Enables the comparison of both Rx Mailbox filter's IDE and RTR bit with their corresponding bits within the incoming frame. Mask bits do apply.
#0 : 0
Rx Mailbox filter's IDE bit is always compared and RTR is never compared despite mask bits.
End of enumeration elements list.
RRS : no description available
bits : 17 - 17 (1 bit)
access : read-write
Enumeration:
#1 : 1
Remote Request Frame is stored
#0 : 0
Remote Response Frame is generated
End of enumeration elements list.
MRP : no description available
bits : 18 - 18 (1 bit)
access : read-write
Enumeration:
#1 : 1
Matching starts from Mailboxes and continues on Rx FIFO
#0 : 0
Matching starts from Rx FIFO and continues on Mailboxes
End of enumeration elements list.
TASD : no description available
bits : 19 - 23 (5 bit)
access : read-write
RFEN : no description available
bits : 24 - 27 (4 bit)
access : read-write
WRMFRZ : no description available
bits : 28 - 28 (1 bit)
access : read-write
Enumeration:
#1 : 1
Enable unrestricted write access to FlexCAN memory
#0 : 0
Keep the write access restricted in some regions of FlexCAN memory
End of enumeration elements list.
Message Buffer 44 CS Register
address_offset : 0x340 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 44 ID Register
address_offset : 0x344 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 44 WORD0 Register
address_offset : 0x348 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 44 WORD1 Register
address_offset : 0x34C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 45 CS Register
address_offset : 0x350 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 45 ID Register
address_offset : 0x354 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 45 WORD0 Register
address_offset : 0x358 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 45 WORD1 Register
address_offset : 0x35C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 46 CS Register
address_offset : 0x360 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 46 ID Register
address_offset : 0x364 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 46 WORD0 Register
address_offset : 0x368 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 46 WORD1 Register
address_offset : 0x36C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 47 CS Register
address_offset : 0x370 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 47 ID Register
address_offset : 0x374 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 47 WORD0 Register
address_offset : 0x378 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 47 WORD1 Register
address_offset : 0x37C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Error and Status 2 Register
address_offset : 0x38 Bytes (0x0)
size : 32 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
IMB : no description available
bits : 13 - 13 (1 bit)
access : read-only
Enumeration:
#1 : 1
If ESR2[VPS] is asserted, there is at least one inactive Mailbox. LPTM content is the number of the first one.
#0 : 0
If ESR2[VPS] is asserted, the ESR2[LPTM] is not an inactive Mailbox.
End of enumeration elements list.
VPS : no description available
bits : 14 - 14 (1 bit)
access : read-only
Enumeration:
#1 : 1
Contents of IMB and LPTM are valid
#0 : 0
Contents of IMB and LPTM are invalid
End of enumeration elements list.
LPTM : no description available
bits : 16 - 22 (7 bit)
access : read-only
Message Buffer 48 CS Register
address_offset : 0x380 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 48 ID Register
address_offset : 0x384 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 48 WORD0 Register
address_offset : 0x388 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 48 WORD1 Register
address_offset : 0x38C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 49 CS Register
address_offset : 0x390 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 49 ID Register
address_offset : 0x394 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 49 WORD0 Register
address_offset : 0x398 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 49 WORD1 Register
address_offset : 0x39C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 50 CS Register
address_offset : 0x3A0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 50 ID Register
address_offset : 0x3A4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 50 WORD0 Register
address_offset : 0x3A8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 50 WORD1 Register
address_offset : 0x3AC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 51 CS Register
address_offset : 0x3B0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 51 ID Register
address_offset : 0x3B4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 51 WORD0 Register
address_offset : 0x3B8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 51 WORD1 Register
address_offset : 0x3BC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 52 CS Register
address_offset : 0x3C0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 52 ID Register
address_offset : 0x3C4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 52 WORD0 Register
address_offset : 0x3C8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 52 WORD1 Register
address_offset : 0x3CC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 53 CS Register
address_offset : 0x3D0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 53 ID Register
address_offset : 0x3D4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 53 WORD0 Register
address_offset : 0x3D8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 53 WORD1 Register
address_offset : 0x3DC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 54 CS Register
address_offset : 0x3E0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 54 ID Register
address_offset : 0x3E4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 54 WORD0 Register
address_offset : 0x3E8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 54 WORD1 Register
address_offset : 0x3EC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 55 CS Register
address_offset : 0x3F0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 55 ID Register
address_offset : 0x3F4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 55 WORD0 Register
address_offset : 0x3F8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 55 WORD1 Register
address_offset : 0x3FC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Control 1 Register
address_offset : 0x4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
PROP_SEG : no description available
bits : 0 - 2 (3 bit)
access : read-write
LOM : no description available
bits : 3 - 3 (1 bit)
access : read-write
Enumeration:
#1 : 1
FLEXCAN module operates in Listen Only Mode
#0 : 0
Listen Only Mode is deactivated
End of enumeration elements list.
LBUF : no description available
bits : 4 - 4 (1 bit)
access : read-write
Enumeration:
#1 : 1
Lowest number buffer is transmitted first
#0 : 0
Buffer with highest priority is transmitted first
End of enumeration elements list.
TSYN : no description available
bits : 5 - 5 (1 bit)
access : read-write
Enumeration:
#1 : 1
Timer Sync feature enabled
#0 : 0
Timer Sync feature disabled
End of enumeration elements list.
BOFF_REC : no description available
bits : 6 - 6 (1 bit)
access : read-write
Enumeration:
#1 : 1
Automatic recovering from Bus Off state disabled
#0 : 0
Automatic recovering from Bus Off state enabled, according to CAN Spec 2.0 part B
End of enumeration elements list.
SMP : no description available
bits : 7 - 7 (1 bit)
access : read-write
Enumeration:
#1 : 1
Three samples are used to determine the value of the received bit: the regular one (sample point) and 2 preceding samples, a majority rule is used
#0 : 0
Just one sample is used to determine the bit value
End of enumeration elements list.
RWRN_MSK : no description available
bits : 10 - 10 (1 bit)
access : read-write
Enumeration:
#1 : 1
Rx Warning Interrupt enabled
#0 : 0
Rx Warning Interrupt disabled
End of enumeration elements list.
TWRN_MSK : no description available
bits : 11 - 11 (1 bit)
access : read-write
Enumeration:
#1 : 1
Tx Warning Interrupt enabled
#0 : 0
Tx Warning Interrupt disabled
End of enumeration elements list.
LPB : no description available
bits : 12 - 12 (1 bit)
access : read-write
Enumeration:
#1 : 1
Loop Back enabled
#0 : 0
Loop Back disabled
End of enumeration elements list.
ERR_MSK : no description available
bits : 14 - 14 (1 bit)
access : read-write
Enumeration:
#1 : 1
Error interrupt enabled
#0 : 0
Error interrupt disabled
End of enumeration elements list.
BOFF_MSK : no description available
bits : 15 - 15 (1 bit)
access : read-write
Enumeration:
#1 : 1
Bus Off interrupt enabled
#0 : 0
Bus Off interrupt disabled
End of enumeration elements list.
PSEG2 : no description available
bits : 16 - 18 (3 bit)
access : read-write
PSEG1 : no description available
bits : 19 - 21 (3 bit)
access : read-write
RJW : no description available
bits : 22 - 23 (2 bit)
access : read-write
PRESDIV : no description available
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 56 CS Register
address_offset : 0x400 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 56 ID Register
address_offset : 0x404 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 56 WORD0 Register
address_offset : 0x408 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 56 WORD1 Register
address_offset : 0x40C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 57 CS Register
address_offset : 0x410 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 57 ID Register
address_offset : 0x414 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 57 WORD0 Register
address_offset : 0x418 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 57 WORD1 Register
address_offset : 0x41C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 58 CS Register
address_offset : 0x420 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 58 ID Register
address_offset : 0x424 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 58 WORD0 Register
address_offset : 0x428 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 58 WORD1 Register
address_offset : 0x42C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 59 CS Register
address_offset : 0x430 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 59 ID Register
address_offset : 0x434 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 59 WORD0 Register
address_offset : 0x438 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 59 WORD1 Register
address_offset : 0x43C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
CRC Register
address_offset : 0x44 Bytes (0x0)
size : 32 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
TXCRC : no description available
bits : 0 - 14 (15 bit)
access : read-only
MBCRC : no description available
bits : 16 - 22 (7 bit)
access : read-only
Message Buffer 60 CS Register
address_offset : 0x440 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 60 ID Register
address_offset : 0x444 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 60 WORD0 Register
address_offset : 0x448 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 60 WORD1 Register
address_offset : 0x44C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 61 CS Register
address_offset : 0x450 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 61 ID Register
address_offset : 0x454 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 61 WORD0 Register
address_offset : 0x458 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 61 WORD1 Register
address_offset : 0x45C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 62 CS Register
address_offset : 0x460 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 62 ID Register
address_offset : 0x464 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 62 WORD0 Register
address_offset : 0x468 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 62 WORD1 Register
address_offset : 0x46C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 63 CS Register
address_offset : 0x470 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 63 ID Register
address_offset : 0x474 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 63 WORD0 Register
address_offset : 0x478 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 63 WORD1 Register
address_offset : 0x47C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Rx FIFO Global Mask Register
address_offset : 0x48 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
FGM31_FGM0 : no description available
bits : 0 - 31 (32 bit)
access : read-write
Enumeration:
#1 : 1
The corresponding bit in the filter is checked
#0 : 0
The corresponding bit in the filter is "don't care"
End of enumeration elements list.
Rx FIFO Information Register
address_offset : 0x4C Bytes (0x0)
size : 32 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
IDHIT : no description available
bits : 0 - 8 (9 bit)
access : read-only
Free Running Timer Register
address_offset : 0x8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIMER : no description available
bits : 0 - 15 (16 bit)
access : read-write
Message Buffer 0 CS Register
address_offset : 0x80 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 0 ID Register
address_offset : 0x84 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 0 WORD0 Register
address_offset : 0x88 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
RXIMR
address_offset : 0x880 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x884 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x888 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x88C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x890 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x894 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x898 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x89C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8A0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8A4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8A8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8AC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8B0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8B4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8B8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8BC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
Message Buffer 0 WORD1 Register
address_offset : 0x8C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
RXIMR
address_offset : 0x8C0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8C4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8C8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8CC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8D0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8D4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8D8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8DC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8E0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8E4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8E8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8EC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8F0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8F4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8F8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x8FC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
Message Buffer 1 CS Register
address_offset : 0x90 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
RXIMR
address_offset : 0x900 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x904 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x908 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x90C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x910 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x914 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x918 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x91C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x920 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x924 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x928 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x92C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x930 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x934 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x938 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x93C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
Message Buffer 1 ID Register
address_offset : 0x94 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
RXIMR
address_offset : 0x940 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x944 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x948 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x94C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x950 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x954 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x958 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x95C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x960 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x964 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x968 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x96C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x970 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x974 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x978 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
RXIMR
address_offset : 0x97C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
MI : MI
bits : 0 - 31 (32 bit)
access : read-write
Message Buffer 1 WORD0 Register
address_offset : 0x98 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 1 WORD1 Register
address_offset : 0x9C Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Glitch Filter Width Registers
address_offset : 0x9E0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
GFWR : no description available
bits : 0 - 7 (8 bit)
access : read-write
Message Buffer 2 CS Register
address_offset : 0xA0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 2 ID Register
address_offset : 0xA4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 2 WORD0 Register
address_offset : 0xA8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 2 WORD1 Register
address_offset : 0xAC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 3 CS Register
address_offset : 0xB0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 3 ID Register
address_offset : 0xB4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 3 WORD0 Register
address_offset : 0xB8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 3 WORD1 Register
address_offset : 0xBC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 4 CS Register
address_offset : 0xC0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 4 ID Register
address_offset : 0xC4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 4 WORD0 Register
address_offset : 0xC8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 4 WORD1 Register
address_offset : 0xCC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 5 CS Register
address_offset : 0xD0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 5 ID Register
address_offset : 0xD4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 5 WORD0 Register
address_offset : 0xD8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 5 WORD1 Register
address_offset : 0xDC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 6 CS Register
address_offset : 0xE0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 6 ID Register
address_offset : 0xE4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 6 WORD0 Register
address_offset : 0xE8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 6 WORD1 Register
address_offset : 0xEC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 7 CS Register
address_offset : 0xF0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
TIME_STAMP : Free-Running Counter Time stamp. This 16-bit field is a copy of the Free-Running Timer, captured for Tx and Rx frames at the time when the beginning of the Identifier field appears on the CAN bus.
bits : 0 - 15 (16 bit)
access : read-write
DLC : Length of the data to be stored/transmitted.
bits : 16 - 19 (4 bit)
access : read-write
RTR : Remote Transmission Request. One/zero for remote/data frame.
bits : 20 - 20 (1 bit)
access : read-write
IDE : ID Extended. One/zero for extended/standard format frame.
bits : 21 - 21 (1 bit)
access : read-write
SRR : Substitute Remote Request. Contains a fixed recessive bit.
bits : 22 - 22 (1 bit)
access : read-write
CODE : Reserved
bits : 24 - 27 (4 bit)
access : read-write
Message Buffer 7 ID Register
address_offset : 0xF4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EXT : Contains extended (LOW word) identifier of message buffer.
bits : 0 - 17 (18 bit)
access : read-write
STD : Contains standard/extended (HIGH word) identifier of message buffer.
bits : 18 - 28 (11 bit)
access : read-write
PRIO : Local priority. This 3-bit fieldis only used when LPRIO_EN bit is set in MCR and it only makes sense for Tx buffers. These bits are not transmitted. They are appended to the regular ID to define the transmission priority.
bits : 29 - 31 (3 bit)
access : read-write
Message Buffer 7 WORD0 Register
address_offset : 0xF8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_3 : Data byte 3 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_2 : Data byte 2 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_1 : Data byte 1 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_0 : Data byte 0 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Message Buffer 7 WORD1 Register
address_offset : 0xFC Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DATA_BYTE_7 : Data byte 7 of Rx/Tx frame.
bits : 0 - 7 (8 bit)
access : read-write
DATA_BYTE_6 : Data byte 6 of Rx/Tx frame.
bits : 8 - 15 (8 bit)
access : read-write
DATA_BYTE_5 : Data byte 5 of Rx/Tx frame.
bits : 16 - 23 (8 bit)
access : read-write
DATA_BYTE_4 : Data byte 4 of Rx/Tx frame.
bits : 24 - 31 (8 bit)
access : read-write
Is something missing? Is something wrong? can you help correct it ? Please contact us at info@chipselect.org !