\n
address_offset : 0x0 Bytes (0x0)
size : 0x20 byte (0x0)
mem_usage : registers
protection : not protected
Control register.
address_offset : 0x0 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DELAYVAL : Tick interval value. The delay will be equal to DELAYVAL + 1 periods of the timer clock. The minimum usable value is 1, for a delay of 2 timer clocks. A value of 0 stops the timer.
bits : 0 - 30 (31 bit)
access : read-write
REPEAT : Repeat delay. 0 = One-time delay. 1 = Delay repeats continuously.
bits : 31 - 31 (1 bit)
access : read-write
Capture register .
address_offset : 0x20 Bytes (0x0)
size : 32 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
CAP_VALUE : Capture value for the related capture event (UTICK_CAPn. Note: the value is 1 lower than the actual value of the Micro-tick Timer at the moment of the capture event.
bits : 0 - 30 (31 bit)
access : read-only
VALID : Capture Valid. When 1, a value has been captured based on a transition of the related UTICK_CAPn pin. Cleared by writing to the related bit in the CAPCLR register.
bits : 31 - 31 (1 bit)
access : read-only
Capture register .
address_offset : 0x34 Bytes (0x0)
size : 32 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
CAP_VALUE : Capture value for the related capture event (UTICK_CAPn. Note: the value is 1 lower than the actual value of the Micro-tick Timer at the moment of the capture event.
bits : 0 - 30 (31 bit)
access : read-only
VALID : Capture Valid. When 1, a value has been captured based on a transition of the related UTICK_CAPn pin. Cleared by writing to the related bit in the CAPCLR register.
bits : 31 - 31 (1 bit)
access : read-only
Status register.
address_offset : 0x4 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
INTR : Interrupt flag. 0 = No interrupt is pending. 1 = An interrupt is pending. A write of any value to this register clears this flag.
bits : 0 - 0 (1 bit)
access : read-write
ACTIVE : Active flag. 0 = The Micro-Tick Timer is stopped. 1 = The Micro-Tick Timer is currently active.
bits : 1 - 1 (1 bit)
access : read-write
Capture register .
address_offset : 0x4C Bytes (0x0)
size : 32 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
CAP_VALUE : Capture value for the related capture event (UTICK_CAPn. Note: the value is 1 lower than the actual value of the Micro-tick Timer at the moment of the capture event.
bits : 0 - 30 (31 bit)
access : read-only
VALID : Capture Valid. When 1, a value has been captured based on a transition of the related UTICK_CAPn pin. Cleared by writing to the related bit in the CAPCLR register.
bits : 31 - 31 (1 bit)
access : read-only
Capture register .
address_offset : 0x68 Bytes (0x0)
size : 32 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
CAP_VALUE : Capture value for the related capture event (UTICK_CAPn. Note: the value is 1 lower than the actual value of the Micro-tick Timer at the moment of the capture event.
bits : 0 - 30 (31 bit)
access : read-only
VALID : Capture Valid. When 1, a value has been captured based on a transition of the related UTICK_CAPn pin. Cleared by writing to the related bit in the CAPCLR register.
bits : 31 - 31 (1 bit)
access : read-only
Capture configuration register.
address_offset : 0x8 Bytes (0x0)
size : 32 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
CAPEN0 : Enable Capture 0. 1 = Enabled, 0 = Disabled.
bits : 0 - 0 (1 bit)
access : read-write
CAPEN1 : Enable Capture 1. 1 = Enabled, 0 = Disabled.
bits : 1 - 1 (1 bit)
access : read-write
CAPEN2 : Enable Capture 2. 1 = Enabled, 0 = Disabled.
bits : 2 - 2 (1 bit)
access : read-write
CAPEN3 : Enable Capture 3. 1 = Enabled, 0 = Disabled.
bits : 3 - 3 (1 bit)
access : read-write
CAPPOL0 : Capture Polarity 0. 0 = Positive edge capture, 1 = Negative edge capture.
bits : 8 - 8 (1 bit)
access : read-write
CAPPOL1 : Capture Polarity 1. 0 = Positive edge capture, 1 = Negative edge capture.
bits : 9 - 9 (1 bit)
access : read-write
CAPPOL2 : Capture Polarity 2. 0 = Positive edge capture, 1 = Negative edge capture.
bits : 10 - 10 (1 bit)
access : read-write
CAPPOL3 : Capture Polarity 3. 0 = Positive edge capture, 1 = Negative edge capture.
bits : 11 - 11 (1 bit)
access : read-write
Capture clear register.
address_offset : 0xC Bytes (0x0)
size : 32 bit
access : write-only
reset_value : 0x0
reset_Mask : 0x0
CAPCLR0 : Clear capture 0. Writing 1 to this bit clears the CAP0 register value.
bits : 0 - 0 (1 bit)
access : write-only
CAPCLR1 : Clear capture 1. Writing 1 to this bit clears the CAP1 register value.
bits : 1 - 1 (1 bit)
access : write-only
CAPCLR2 : Clear capture 2. Writing 1 to this bit clears the CAP2 register value.
bits : 2 - 2 (1 bit)
access : write-only
CAPCLR3 : Clear capture 3. Writing 1 to this bit clears the CAP3 register value.
bits : 3 - 3 (1 bit)
access : write-only
Is something missing? Is something wrong? can you help correct it ? Please contact us at info@chipselect.org !