Registers
RNG_IMR
Interrupt Masking Register
address_offset : 0x100 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0
ISR
Interrupt Status Register
address_offset : 0x104 Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
ICR
Interrupt status bit Clear Register
address_offset : 0x108 Bytes (0x0)
access : write-only
reset_value : 0x0
reset_Mask : 0x0
CONFIG
TRNG Configuration Register
address_offset : 0x10C Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0
VALID
TRNG Valid register
address_offset : 0x110 Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA0
EHR Data register
address_offset : 0x114 Bytes (0x0)
size : -1 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA1
EHR Data register
address_offset : 0x118 Bytes (0x0)
size : -1 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA2
EHR Data register
address_offset : 0x11C Bytes (0x0)
size : -1 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA3
EHR Data register
address_offset : 0x120 Bytes (0x0)
size : -1 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA4
EHR Data register
address_offset : 0x124 Bytes (0x0)
size : -1 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA5
EHR Data register
address_offset : 0x128 Bytes (0x0)
size : -1 bit
access : read-only
reset_value : 0x0
reset_Mask : 0x0
RND_SOURCE_ENABLE
Random Source Enable registe
address_offset : 0x12C Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0
SAMPLE_CNT1
Sample Counter register
address_offset : 0x130 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0
AUTOCORR_STATISTIC
Autocorrelation Statistic register
address_offset : 0x134 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0
DEBUG_CONTROL
TRNG Debug Control register
address_offset : 0x138 Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
SW_RESET
TRNG Software Reset Register
address_offset : 0x140 Bytes (0x0)
access : write-only
reset_value : 0x0
reset_Mask : 0x0
BUSY
TRNG Busy status register
address_offset : 0x1B8 Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
RST_BITS_COUNTER
Reset Bits Counter register
address_offset : 0x1BC Bytes (0x0)
access : write-only
reset_value : 0x0
reset_Mask : 0x0
RST_BIST_COUNTER0
RNG BIST Counter register
address_offset : 0x1E0 Bytes (0x0)
size : -1 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
RST_BIST_COUNTER1
RNG BIST Counter register
address_offset : 0x1E4 Bytes (0x0)
size : -1 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
RST_BIST_COUNTER2
RNG BIST Counter register
address_offset : 0x1E8 Bytes (0x0)
size : -1 bit
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA[0]
EHR Data register
address_offset : 0x228 Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA[1]
EHR Data register
address_offset : 0x340 Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
RST_BIST_COUNTER[0]
RNG BIST Counter register
address_offset : 0x3C0 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA[2]
EHR Data register
address_offset : 0x45C Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA[3]
EHR Data register
address_offset : 0x57C Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
RST_BIST_COUNTER[1]
RNG BIST Counter register
address_offset : 0x5A4 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA[4]
EHR Data register
address_offset : 0x6A0 Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0
RST_BIST_COUNTER[2]
RNG BIST Counter register
address_offset : 0x78C Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0
EHR_DATA[5]
EHR Data register
address_offset : 0x7C8 Bytes (0x0)
access : read-only
reset_value : 0x0
reset_Mask : 0x0