\n

OPS

Peripheral Memory Blocks

address_offset : 0x0 Bytes (0x0)
size : 0x8 byte (0x0)
mem_usage : registers
protection : not protected

Registers

OPA_CTL (CTL)

OPA_STATUS (STATUS)


OPA_CTL (CTL)

OP Amplifier Control Register
address_offset : 0x0 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0

OPA_CTL OPA_CTL read-write 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Resets to Resets to 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OPEN0 OPEN1 OPSMTEN0 OPSMTEN1 OPAIE0 OPAIE1

OPEN0 : OP Amplifier 0 Enable Bit\nNote: OP Amplifier 0 output needs wait stable 20 s after OPEN0 is first set.
bits : 0 - 0 (1 bit)
access : read-write

Enumeration:

#0 : 0

Disabled

#1 : 1

Enabled

End of enumeration elements list.

OPEN1 : OP Amplifier 1 Enable Bit\nNote: OP Amplifier 1 output needs wait stable 20 s after OPEN1 is first set.
bits : 1 - 1 (1 bit)
access : read-write

Enumeration:

#0 : 0

Disabled

#1 : 1

Enabled

End of enumeration elements list.

OPSMTEN0 : OP Amplifier 0 Schmitt Trigger Non-Inverting Buffer Enable Bit\n
bits : 4 - 4 (1 bit)
access : read-write

Enumeration:

#0 : 0

Disabled

#1 : 1

Enabled

End of enumeration elements list.

OPSMTEN1 : OP Amplifier 1 Schmitt Trigger Non-Inverting Buffer Enable Bit\n
bits : 5 - 5 (1 bit)
access : read-write

Enumeration:

#0 : 0

Disabled

#1 : 1

Enabled

End of enumeration elements list.

OPAIE0 : OP Amplifier 0 Schmitt Trigger Digital Output Interrupt Enable Bit\nThe OPDF0 interrupt flag is set by hardware whenever the OP amplifier 0 Schmitt trigger non-inverting buffer digital output changes state, in the meanwhile, if OPAIE0 is set to 1, a comparator interrupt request is generated.
bits : 8 - 8 (1 bit)
access : read-write

Enumeration:

#0 : 0

OP Amplifier 0 digital output interrupt function Disabled

#1 : 1

OP Amplifier 0 digital output interrupt function Enabled

End of enumeration elements list.

OPAIE1 : OP Amplifier 1 Schmitt Trigger Digital Output Interrupt Enable Bit\nOPDF1 interrupt flag is set by hardware whenever the OP amplifier 1 Schmitt trigger non-inverting buffer digital output changes state, in the meanwhile, if OPAIE1 is set to 1, a comparator interrupt request is generated.
bits : 9 - 9 (1 bit)
access : read-write

Enumeration:

#0 : 0

OP Amplifier 1 digital output interrupt function Disabled

#1 : 1

OP Amplifier 1 digital output interrupt function Enabled

End of enumeration elements list.


OPA_STATUS (STATUS)

OP Amplifier Status Register
address_offset : 0x4 Bytes (0x0)
access : read-write
reset_value : 0x0
reset_Mask : 0x0

OPA_STATUS OPA_STATUS read-write 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Resets to Resets to 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OPDO0 OPDO1 OPDF0 OPDF1

OPDO0 : OP Amplifier 0 Digital Output\n
bits : 0 - 0 (1 bit)
access : read-write

OPDO1 : OP Amplifier 1 Digital Output\n
bits : 1 - 1 (1 bit)
access : read-write

OPDF0 : OP Amplifier 0 Schmitt Trigger Digital Output Interrupt Flag\nOPDF0 interrupt flag is set by hardware whenever the OP amplifier 0 Schmitt trigger non-inverting buffer digital output changes state. This bit is cleared by writing 1 to it.
bits : 4 - 4 (1 bit)
access : read-write

OPDF1 : OP Amplifier 1 Schmitt Trigger Digital Output Interrupt Flag\nOPDF1 interrupt flag is set by hardware whenever the OP amplifier 1 Schmitt trigger non-inverting buffer digital output changes state. This bit is cleared by writing 1 to it.
bits : 5 - 5 (1 bit)
access : read-write



Is something missing? Is something wrong? can you help correct it ? Please contact us at info@chipselect.org !